<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-01 12-08-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 41 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 10 kHz 18719 0,2244
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -0,76 dBr 0,3 dBr 1,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 12:08, 1.02.2024
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 10 kHz MIN: 8 kHz % above 77 kHz: 0,2244 Acquired: 2024/02/01 12:08:26 Total samples: 18719 Equivalent time: 0:15:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,3 dBr MIN: -1,9 dBr AVE: -0,76 dBr % above 0,2 dBr: 1,0 Last value: -0,6 dBr (2024/02/01 12:08:26) 11:54 11:56 11:58 12:00 12:02 12:04 12:06 12:08 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality